Energy saving frequency conversion contact riveting machine

Asn-1.5t contact machine
1、 Function
1. Stable voltage, easy replacement and high accuracy;
2. Suitable for processing: computer terminals, DC terminals, AC terminals, single chip terminals, and joint terminals
3. Light structure, easy to move the workplace, low operating sound;
4. It is suitable for OTP model, OTP straight module, OTP reverse direct module, 2000 ා and 950 ා.
2、 Specifications and accessories
1. Riveting press
form ASY-1.5T
ability 1500kg
trip 5mm(30mm)
Power Supply 220v 50/60Hz
volume 350 X 320 X600 mm
weight 85 kg
ambient temperature -40 ℃~ + 70 ℃ (non condensing)
work efficiency 6000 times / h
3、 Frequency converter parameter table
key definition Parameter number Parameter meaning / range Factory value
Manual / Auto Key Manual light: green light At the initial power on, the default is automatic state; in manual mode, press the positive and negative inching keys on the panel to make the motor rotate forward and backward to adjust the punch position. The "up / down" button on the pedal is changed to "auto" button.  
Speed key F=50 Speed setting: 45, 50, 55, 60, 65, 70, 75, 80 can be set; fifty
Continuous key n=1 The continuous working times of punch can be adjusted from 1 to 20 one
h=0 The working interval time is 0.0 ~ 2.0 (when the punch stops working continuously, it will work again after a certain interval of time after the punch stops. When h = 0 and N > 1, the motor will not have positioning work, but will run continuously until the completion times. zero
L=00 Spare parameters, no need to modify 00
4、 Abnormal protection and treatment of frequency converter
When the frequency converter of the terminal machine fails, it will stop automatically, and the screen will prompt the cause of the fault in Chinese.
Display code Code meaning processing method Error code
  No abnormal record   zero
E_o Hardware protection Check whether there is short circuit and locked rotor; the motor has not stopped stably and starts rapidly again. one
E_ oCA Over current in acceleration It is generally caused by too fast acceleration. Pay attention to adjust the acceleration time. two
E_ oC Over current in constant speed Pay attention to whether there is sudden load. three
E_ oCd Over current in deceleration Generally caused by too fast deceleration, pay attention to adjust the deceleration time. four
E_ oU Over voltage When the power supply voltage is over-voltage, and the beam reduction or shutdown is too fast, the pump voltage will be too high (the value of deceleration time can be increased) five
E_ oH Drive overheating Check whether the ambient temperature is too high and whether the frequency converter has good heat dissipation and ventilation. six
E_ oL Electronic thermal relay action Check whether the motor power exceeds the power of frequency converter and whether it is in low speed and high current state for a long time (see electronic thermal relay: overload protection characteristic diagram). seven
E_ OL2 Over torque protection action Over the set over torque value, check the torque related parameters and external torque. eight
E_ LU low pressure If the power input is too low, whether the load is too heavy to cause the bus voltage drop, there is power failure. nine
E_ CH Chain break The terminals set as interlock in d098-d101 are in disconnected state, and normal operation can be resumed only after reconnecting and pressing reset. ten
ACL_ Hardware protection of frequency converter Protection caused by multiple unexplained external errors during operation. eleven