Energy saving frequency conversion contact riveting machine

Asn-1.5t contact machine
1、 Function
1. It is suitable for contact semi-automatic riveting, semi-automatic parts riveting, etc.
2. The riveting speed of parts is fast;
3. Light structure;
4. Low noise;
5. Energy saving.
2、 Specifications and accessories
1. Riveting press
form AS1T AS1.5T AS2T
Capacity (kg) one thousand one thousand and five hundred two thousand
Stroke (mm) 5-40
Power Supply 220V/50HZ/60HZ
ambient temperature -40 ℃~ + 70 ℃ (non condensing)
work efficiency 6000 times / h
Vibrating disk Linear feeder / vibration rate: adjustable
Power Supply 220V AC/50HZ/60HZ
3、 Frequency converter parameter table
Parameter number Parameter meaning / range Factory value
P000 The main frequency is 0.1Hz ~ p003. The output is also limited by the maximum operating frequency of p003 70.00Hz
P001 Upper limit of inverter output frequency 70.00 Hz
P002 Continuous working times of punch of riveting press one
P003 Maximum operating frequency of frequency converter 90.00 Hz
P004 Acceleration time selection: 0.1 ~ 655.00s (the time required to rise from 0 speed to the highest operating frequency) 0.10s
P005 Deceleration time selection: 0.1 ~ 655.00s (time required to reduce from the highest operating frequency to 0 speed) 0.10s
P006 Jog frequency setting 6.00Hz
P007 Standby, please do not set --
P008 Standby, please do not set zero
P009 Response time of riveting machine (1-20ms) 6ms
P010 Standby, please do not set --
P011 Out1 output delay pull in time setting 0ms
P012 Out1 output pull in holding time setting zero
P013 Out2 output delay pull in time setting zero
P014 Out2 output pull in holding time setting zero
P015 Out3 output delay pull in time setting zero
P016 Out3 output pull in holding time setting zero
P017 Out4 output delay pull in time setting 200ms
P018 Out4 output pull in holding time setting 200ms
P019 Standby, please do not set --
P020 Time out of punch positioning switch of riveting press. The motor is forced to stop over time to prevent the motor from running all the time due to the failure of the positioning switch or other reasons; when the time-out occurs, the decimal points in the first three digits of the nixie tube will light up to remind the user to remove the fault. 3000ms
P021 Standby, please do not set --
P022 Standby, please do not set --
P023 The user can lock the password (p00: 0) to prevent the user from changing the parameter. zero
4、 Abnormal protection and treatment of frequency converter
The inverter will stop automatically. The digital tube displays the error code. Users can refer to the code table and take corresponding measures.
Display code Code meaning processing method Error code
  No abnormal record   zero
E_o Hardware protection Check whether there is short circuit and locked rotor; the motor has not stopped stably and starts rapidly again. one
E_ oCA Over current in acceleration It is generally caused by too fast acceleration. Pay attention to adjust the acceleration time. two
E_ oC Over current in constant speed Pay attention to whether there is sudden load. three
E_ oCd Over current in deceleration Generally caused by too fast deceleration, pay attention to adjust the deceleration time. four
E_ oU Over voltage When the power supply voltage is over-voltage, and the beam reduction or shutdown is too fast, the pump voltage will be too high (the value of deceleration time can be increased) five
E_ oH Drive overheating Check whether the ambient temperature is too high and whether the frequency converter has good heat dissipation and ventilation. six
E_ oL Electronic thermal relay action Check whether the motor power exceeds the power of frequency converter and whether it is in low speed and high current state for a long time (see electronic thermal relay: overload protection characteristic diagram). seven
E_ OL2 Over torque protection action Over the set over torque value, check the torque related parameters and external torque. eight
E_ LU low pressure If the power input is too low, whether the load is too heavy to cause the bus voltage drop, there is power failure. nine
E_ CH Chain break The terminals set as interlock in d098-d101 are in disconnected state, and normal operation can be resumed only after reconnecting and pressing reset. ten
ACL_ Hardware protection of frequency converter Protection caused by multiple unexplained external errors during operation. eleven